天津护理 ›› 2024, Vol. 32 ›› Issue (3): 259-264.DOI: 10.3969/j.issn.1006-9143.2024.03.002

• 论著 • 上一篇    下一篇

耳鼻咽喉头颈外科护理质量敏感指标体系的构建

何嘉 李鑫 熊莉娟   

  1. (华中科技大学同济医学院附属协和医院,湖北 武汉 430022)
  • 出版日期:2024-06-28 发布日期:2024-06-28
  • 基金资助:
    华中科技大学同济医学院附属协和医院 2022 年度药技护专项基金(F016.01003.22003.179)

Construction of sensitive index system of nursing quality in otolaryngology head and neck surgery

HE Jia, LI Xin, XIONG Lijuan   

  1. (Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan Hubei 430022)
  • Online:2024-06-28 Published:2024-06-28

摘要: 目的:构建耳鼻咽喉头颈外科护理质量敏感指标评价体系,为评价耳鼻咽喉头颈外科专科护理质量提供标准、量化的依据。方法:以 Donabedian 的“结构-过程-结果”三维质量模型为理论框架,采用文献分析法,由专家小组讨论初步筛选指标,编制咨询问卷,运用 Delphi 法进行 2 轮专家咨询,确定耳鼻咽喉头颈外科护理质量敏感指标,应用层次分析法计算各指标权重。结果:2 轮咨询专家积极系数均为 100%,权威系数分别为 0.919、0.934,第 1 轮专家咨询肯德尔和谐系数为 0.218~0.294,第 2 轮为 0.269~0.335(均 P<0.05);所构建的耳鼻咽喉头颈外科护理质量敏感指标体系包含 3 项一级指标、10 项二级指标和 31 项三级指标。一级指标权重结果分别为 0.112、0.444、0.444,二级指标权重结果为 0.028~0.207,三级指标权重结果为 0.005~0.111。结论:构建的耳鼻咽喉头颈外科护理质量敏感指标体系突出专科特点,具有科学性和实用性,可为耳鼻咽喉头颈外科护理质量评价提供参考。

关键词: 耳鼻咽喉头颈外科, 敏感指标, 德尔菲法, 护理质量

Abstract: Objective: To construct a sensitive, scientific, and targeted evaluation system for the quality of nursing care in otolaryngology head and neck surgery, in order to provide a standardized and quantitative basis for evaluating and monitoring the quality of otolaryngology head and neck surgery specialized nursing care. Methods: Based on Donabedian′s "structure process results" theoretical framework, literature analysis, expert groups discussion were performed to access the preliminary screening of indicators, prepared a consultation questionnaire and two rounds of Delphi expert consultation, and then sensitive indicators of nursing quality in otolaryngology head and neck surgery were revised and determined. The weight of each indicators was calculated using analytic hierarchy process. Results: The positivity coefficients of the two rounds of consultation experts were both 100%, the authority coefficients were 0.919 and 0.934 respectively. The Kendall harmony coefficients of the first round of expert consultation were 0.218~0.294, and the second round were 0.269~0.335 (both P<0.05). The constructed otolaryngology head and neck surgery nursing quality sensitive indicator system included 3 first level indicators, 10 second level indicators and 31 third level indicators. The weight results of the first level indicators were 0.112, 0.444, and 0.444 respectively, the weight results of the second level indicators were 0.028~0.207, and the weight results of the third level indicators were 0.005~0.111. Conclusion: The constructed sensitive indicators for the nursing quality of otolaryngology head and neck surgery highlight the characteristics of specialized departments, and are scientific and practical, and can provide reference for the evaluation of nursing quality in otolaryngology head and neck surgery.

Key words: Otolaryngology head and neck surgery, Sensitive indicators, Delphi method, Nursing quality